Inspection History: ELECTRIC - ABOVE CEILING

Permit Number - T09CM02200

Inspection Description - ELECTRIC - ABOVE CEILING

Inspection Status - Approved

Date Description Inspector Results Comments
10/01/2009 ELECTRIC - ABOVE CEILING Approved IVRS - Inspection :*
08/27/2009 ELECTRIC - ABOVE CEILING Partial Approval IVRS - Inspection :*
1) STILL MISSING KNOCKOUT IN LIGHT BOX NORTH EAST CORNER
2) SEAL OPEN KNOCKOUT THE OK, WILL CHECK AT FINAL
08/26/2009 ELECTRIC - ABOVE CEILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEAL OPEN KNOCKOUTS IN JUNCTION BOXES
2) REMOVE ALL OLD WIRING NOT TO BE REUSED
3) PROPERLY MAKE UP GROUND SPLICES IN BOXES. USE WIRE NUTS OR BARREL CRIMPS
4) SECURE RECEPTACLE BOX AT RESTROOM WALL AND STRAP METAL FLEX
08/25/2009 ELECTRIC - ABOVE CEILING Denied IVRS - Inspection :
There is no plan or job inspection card on site.| 925*
1) NO PLANS OR PERSONEL ON SITE