Permit: T09CM02183

Parcel: 141310980

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T09CM02183

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
09/08/2009 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/04/2009 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSED 2 X BLKS FOR #3 SHEARWALL DRYWALL 2ND FLOOR EAST
2) CANNOT READ H.D. OR P.A.'S PLAN PRINT TO SMALL, PLUS 1ST/2ND FLLOR STRAPS (TYPE) ?
3) NEED RETRO H.D.'S REAR WALL (MISSED) CONC.
4) NAIL (ALL) STUDS TO OSB ATTACHING HOLDOWN HARDWARE, (ALL)
5) 2ND FLOOR TWO POP IUTS, BEARING WALL, BLK BELOW BETWEEN GARGE TRUSSES FOR WEIGHT, RESTS ON ROOF OSB ONLY FALLS BETWEEN TRUSSES
6) BLK BETWEEN FLOORS AT ROOF GIRDER BEARING, NEXT TO GUARD RAIL
8) DBL CRIPPLE UNDER NORTH END ROOF GIRDER, REAR SLIDER
9) PLANS ARE NOT LEDGIABLE