Permit: T09CM02163

Parcel: 141310960

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T09CM02163

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
09/15/2009 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
09/11/2009 PLUMBING - INTERMEDIATE Not ready for Inspection 1) DWV TEST
09/10/2009 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
09/09/2009 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. REMOVE MESH STAPLES AROUND HOME RUNS
2. SECONDARY CONDENSATE DRAIN MUST TERMINATE ABOVE A WINDOW OR OTHER OBVIOUS LOCATION
3. TIGHTEN ANCHOR BOLT AT S.W. CORNER OF HOUSE
4. SHIM HEADER/TRIMMER GAPS WHERE NEEDED
5. NO WATER IN DWV TEST
6. WATER SUPPLY LEAK ABOVE HALL SHOWER
7. SECURE ABS VENT 90 DEG. IN HALL BATH
8. FHA STRAP TOP PLATES AT MASTER ABS OVERBORE AND STUD SHOES NEEDED AT LAV STUD OVERBORES
9. CAULK BOXES UNDER ELEC. PANEL