Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/15/2009 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 09/11/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | 1) DWV TEST | |
| 09/10/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 09/09/2009 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. REMOVE MESH STAPLES AROUND HOME RUNS 2. SECONDARY CONDENSATE DRAIN MUST TERMINATE ABOVE A WINDOW OR OTHER OBVIOUS LOCATION 3. TIGHTEN ANCHOR BOLT AT S.W. CORNER OF HOUSE 4. SHIM HEADER/TRIMMER GAPS WHERE NEEDED 5. NO WATER IN DWV TEST 6. WATER SUPPLY LEAK ABOVE HALL SHOWER 7. SECURE ABS VENT 90 DEG. IN HALL BATH 8. FHA STRAP TOP PLATES AT MASTER ABS OVERBORE AND STUD SHOES NEEDED AT LAV STUD OVERBORES 9. CAULK BOXES UNDER ELEC. PANEL |