Permit: T09CM02145

Parcel: 141316530


Addresses:

7805 E TREETOP RD


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T09CM02145

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/09/2009 FRAMING Approved
10/13/2009 FRAMING Partial Approval IVRS - Inspection :*
1) DAMAGED WEB ON TRUSS REPLACED, NEED REPAIR DETAIL FOR OUR RECORDS DEPT.
10/08/2009 FRAMING Partial Approval IVRS - Inspection :*
1) A01 TRUSS DAMAGE
10/07/2009 FRAMING Partial Approval IVRS - Inspection :*
1) OK TO INSULATE
2) GARAGE TO HOUSE SHEARWALL, TWO H.D.'S SOUTH OF MAN DOOR, OSB TO BE NAILED TO STUDS ATTACHED TO H.D.
10/06/2009 FRAMING Not ready for Inspection IVRS - Inspection :*
1) FROM LAST INSPECTION ITEMS NOT DONE 1,2,3 & 6
10/05/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DRYWALL BACKING HALL TUB AND MASTER
2) SECURE WALL TOP PLATE HALL BATH TO BEDROOM
3) TRUSS WEB CUT 4TH TRUSS FROM REAR WALL, MARKED ON FLOOR BELOW, SAW KERF IN WEB
4) BLOCK MECH DUCT MSTR TOILET
5) SHEARWALL ADD STUD NEXT TO DRYER BOX
6) INTERIOR SHEARWALLS, NAIL ALL STUDS TO OSB AT H.D.'S