Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/16/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 11/05/2009 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) IN THE FUTURE PLEASE HAVE ALL REQUIRED INSPECTIONS ON ACTIVITY CARD 2) PROVIDE DETAIL FOR FRAME AND PANEL SUPPORT TO FRAME WORK AND ROOF 2) INSULATE ALL HOT PIPING 3) PROVIDE CORRECT SUPPORT FOR ALL PIPING ON ROOF AND IN HEATER CLOSET 4) PRESSURE RELIEF TO BE TERMINATED 6" TO 24" FROM FINISH GRADE 5) REMOVE AND PERMANENTLY CAP GAS PIPING 6) TERMINATE TEMPERATURE PRESSURE RELIEF 1" ABOVE DRIP PAN AND HAVE ALTERNATE FORM OF T & P RELIEF FORM LEFT ON SITE SIGNED BY OWNER AT SITE 7) INSTALL ALL PIPING PER APPROVED PLAN 8) INSTALL DRIP PAN UNDER DRAIN BACK TANK ON ELEVATED PLENIUM MADE OF WOOD |