Permit: T09CM02139

Parcel: 135021830


Addresses:

6434 E CALLE BOOTIS

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
10/15/2009 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
10/13/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) SORRY VERY BUSY TODAY, LEAVE PLANS AND PERMIT NEXT TIME
2) SHOWER OK AT INTERMEDIATE WILL LOCK FOR A C.O.
3) TOILET VERT TO HORIZONTAL REQUIRES LONG SWEEP AT VENT 90 DEGREE
4) C/0 FOR MAIN TRUNK VERT TO HORIZONTAL LONG SWEEP OK A 45 DEGREE IN PLUMBING 45 DEGREE CONSIDERED VERT.
5) LAV USE LONG SWEEP VERT TO HORIZONTAL NO C/O REQUIRED NOT OVER 5'-0" FROM MAIN TRUNK
6) GO AHEAD AND GLUE UP AFTER FIXED, TEST I WILL CHECK INSIDE AT NEXT INSP. CALL BACK AFTER YOUR ALL GLUED TOGETHER