Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T09CM02128
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/11/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
08/31/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) TERMINATE PRESSURE RELIEF 6" TO 24" FROM FINISH GRADE WHERE IT IS VISIBLE AT DOWNWARD DIRECTION PER PLAN 2) NOTE: EXTENSION LADDER MUST EXTEND MINIMUM 3' ABOVE ROOF FOR SAFE USE |
|
08/20/2009 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. IT IS THE CONTRACTORS RESPONSIBILITY TO PROVIDE SAFE ACCESS TO PANEL AT TIME OF INSPECTION 2. EXPANSION TANK NEEDS TO BE PROPERLY SUPPORTED AND SECURED. IT IS TOO HEAVY TO BE SUPPORTED BY PIPING. LIST NOT COMPLETE FOR ACCESS ISSUE |