Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/22/2009 FRAMING Approved IVRS - Inspection :*
09/18/2009 FRAMING Partial Approval IVRS - Inspection :*
1) WALL LATH NOT COMPLETE
2) PARAPETS NOT COMPLETE
3) MORE SUPPORT FOR H20 HTR
4) BLOCK AT TOP OF #2 SHEARWALL TRANSFER AT DRYWALL INSPECTION WILL LOOK FO PERIMETER NAILING
5) WRONG SIZE NAILS IN P.A. STRAPS GARAGE
6) MISSING FIRE BLOCK LAUNDRY
7) NAIL PROTECTION DBL LAV; GARAGE SIDE, STUDS OVER DRILLED-USE FHA STRAPS
8) NEED GAS CONNECTION TO FIREPLACE, UNDER TEST (IT'S CONCEALED)
9) PEX TO BE 12" MINIMUM FROM LIGHT CANS, KIT AND FRONT ENTRY TO BEDROOMS
10) GAS TEST WAS HOLDING, NEED FIREPLACE HOOKED UP AND TESTED
11) ADDRESS NUMBER ON ELECTRIC PANEL (SHARPIE) OK