Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/22/2009 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* 1) CORRECTIONS HAVE BEEN MADE |
|
| 09/17/2009 | MECHANICAL - FINAL | Partial Approval | WIRE SPLICES ON HIGH VOLTAGE MUST BE DONE IN AN APPROVED J BOX FOR ALL MINI SPLIT FOR COILS. | |
| 09/16/2009 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :* | |
| 09/01/2009 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE MINIMUM 15A DISCONNECT SWITCH AT EACH FAN COIL 2) PROVIDE A HOSE CLAMP ON BARBED FITTING 3) CONNECT OVERFLOW SENSORS 4) SECURE THE DRAIN HOSE CONNECTIONS FROM FAN COIL INTO PUMPS-ALL FUJITSU UNITS 5) USE AN APPROVED EQUIPMENT CORD AT RHEEM FAN COIL 6) SECURE THE VENT CONNECTOR 7) PROVIDE PURPLE PRIMER ON ALL PVC FITTINGS PRIOR TO GLUE 8) ELECTRIC ON ROOF OK |