Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/25/2010 | BUILDING - FINAL | Approved | CERTS TURNED IN | |
| 05/12/2010 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) NEED STUCCO AND INSULATION CERTS |
|
| 05/11/2010 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LIGHTS, FANS AND SMOKE ALARM SHALL BE ARC FAULT PROTECTED 2) CONDENSATION LINE SHALL HAVE 1/4" PER FOOT SLOPE AND SECURE TO ROOF AT 48" ON CENTER 3) COMPLETE WATER HEATER APPEAL PAPERWORK 4) 21" CLEARANCE REQUIRED IN FRONT OF WATER CLOSET |
|
| 05/07/2010 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PAINT ROOF VENTS ABS 2) LOWER CLEANOUTS TO GRADE 3) VACUUM BREAKER HOSE BIB 4) OVERHANG AT BATHROOM OVER FENCE LINE. FIRE RATED ? WHERE IS PROPERTY LINE ? 5) COMPLETE GRADING SLOPE AWAY FROM BLDG 6) COMPLETE CONDENSATE LINE TO ROOFS EDGE 7) COPPER OR CVPC TPR WATER HEATER. TPR LINE MUST SLOPE DOWNWARD ANGLE OUT-APPEAL REQUIRED 8) GFCI PROTECT OUTLET LIVING ROOM SINK 9) ARC FAULT BEDROOM OUTLETS 10) RELOCATE BATH GFCI OUTLETS PER CODE |