Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T09CM02037
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/08/2009 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
09/23/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) PROVIDE OVERHEAD SUPPORT ON VENT SYSTEM AT 4' INTERVAL FOR ABS PIPING INSTALLED FOR SINK AT LOCTAION NOTE #31 PAGE A2 THIS IS NEW NOT EXISTING 2) SECURE WATER STUB OUTS THIS LOCATION ALSO 3) WATER TEST NEEDS TO BE IN PLACE FOR WATER SYSTEM, WATER IS OFF OR PROVIDE AIR TEST |
|
09/18/2009 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SECURE PIPING IN WALLS, SUPPORT OVER HEAD AND IN WALLS 2) CLEANOUT SHALL RISE VERTICALLY ABOVE FLOW LINE 3) PROVIDE TEST 4) KEEP OPEN DRAIN AND VENT PIPING CAPPED OR PLUG FOR SAFETY |