Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/14/2009 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
| 08/13/2009 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE PROPER DEPTH SOIL MINIMUM 3 1/2". NEW PORCH REQUIRES 2" MINIMUM FROM WEEP 2) EXPANSION JOINT REQUIRED AT EXISTING 3) COMPACT SOIL 95 PERCENT 4) PROVIDE 8" TOE ALL EDGES 5) REMOVE #3 BARS IN FOOTERS TO #4 2 EACH WAY PER DETAIL 3/2 |
|
| 08/12/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) PORCH SLAB TO BE POURED LATER. 2" FROM STUCCO STOP TO SLAB 2) OK PER LEE RAY TO POUR AGAINST STUCCO |