Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T09CM01984
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/13/2009 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
11/10/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
11/06/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) TUB TEST |
|
10/30/2009 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HOT WATER PIPING AT WATER HEATER NEEDS A CAP 2) CLOSET FLANGE IS NOT SECURED 3) ABOVE CEILING PIPE SUPPORTS AT WATER CLOSET 4) LOOP HOT WATER AND COLD WATER, CAP TUB SPOOL AND SHOWER, FOR TEST 5) FILL TUB TO FLOOD LEVEL 6) CONTINUED DENIED INSPECTIONS MAY RESULT IN REINSPECTION FEES |
|
10/27/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
10/26/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* SUGGESTION #1 OF LAST INSPECTION. THIS IS A SAFETY ITEM, YOU WILL BE REFEED IF THIS IS NOT CORRECTED BYNEXT INSPECTION. NO PLANS NEEDED PER LEERAY |
|
10/07/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE TEMP CAPS OR PLUGS ON ALL OPEN DRAINS TO PREVENT THE ESCAPE OF SEWER GARBAGE 2) NEW TUB REQUIRED PROPER INSTALLATION WITH A WATER TEST, INSTALL STRINGER & SECURE AND COMPLETE PIPING 3) SECURE SHOWER VALVE 4) SECURE NEW CLOSET FLANGE 5) SUPPORT ABS REVENT ABOVE CEILING 6) PROVIDE A T & P DRAIN LINE WITH PROPER TERMINATION 7) PROVIDE APPROVED PLANS |