Permit: T09CM01978

Parcel: 116033160


Addresses:

2329 W TUCANA ST

Inspection Status: Approved

Inspection History: STUCCO MESH

Date Description Inspector Results Comments
05/27/2010 STUCCO MESH Approved IVRS - Inspection :*
05/24/2010 STUCCO MESH Partial Approval IVRS - Inspection :*
05/05/2010 STUCCO MESH Partial Approval IVRS - Inspection :*
1. GROUND METAL BOXES
2. SEAL PENETRATIONS
3. NAIL PROTECT PLUMBING AND ELECTRICAL IN CLOSET
4. EXTEND BOND WIRE COPPER TO EXTERIOR
5. MISSING NAILERS IN CLOSET CORNERS
6. SECURE ROMEX 8" FROM BOXES
7. MIXED 12-2/14-2 IN BOXES THROUGHOUT
8. MAKE UP ALL SWITCHES PIGTAIL GROUNDS
9. PROVIDE APPROVED CEILING FAN BOXES
03/04/2010 STUCCO MESH Not ready for Inspection IVRS - Inspection :*
02/23/2010 STUCCO MESH Not ready for Inspection IVRS - Inspection :*
1) CHECK ALL EXT. OSB NAILING 6" ON CENTER ALL EDGES 12" FIELD
2) RECALL 1035