Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T09CM01965
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/19/2009 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
09/30/2009 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) BOXES OVER FILLED-CK ON FINAL 2) OK WALLS AND LIDS |
|
09/29/2009 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : There is no access to the site.| 920* 1) LOCKED, NO ACCESS |
|
09/23/2009 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK CEILINGS EXCEPT BATHROOMS 704, 705, 708 AND 709 2) OK PANEL 705 |
|
09/21/2009 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) USE APPROVED CONNECTORS WITH NM CABLES 2) SEPERATE GROUNDS AND NEUTRALS AT SUB PANELS 3) SECURE NM CABLES WITHIN 12" OF BOXES, CABINETS AND EQUIPMENT |
|
08/31/2009 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK 705-712 FIRE WALL ONLY |
|
08/24/2009 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) MAINTAIN SEPERATION FOR FIRE STOPPING AND BACK TO BACK 2) SECURE SE CABLES WITHIN 8" OF SERVICE 3) PROTECT SE CABLE FROM SHARP METAL BOXES 4) SECURE CABLES ABOVE PANELS |