Permit: T09CM01852

Parcel: 112032000


Addresses:

3309 N CHRISTMAS AV

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
08/26/2009 ROOF NAILING Approved IVRS - Inspection :*
08/25/2009 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED ABS TESTED
2) PROVIDE APPROVED DETAIL FOR ROOF OVER FRAME ONTO EXISTING HOUSE
3) SINCE THERE ARE NO OVER FRAME RAFTER PLATES, THE SHEATHING IS NOT NAILED IN VALLEYS
4) 2 X 4 OVER FRAME RAFTERS ?
5) ROWS OF ROOF SHEATHING NAILING MISSED
6) OVER BORED STUDS FOR ABS NEED FULLY NAILED FHA STRAPS-NOT SCREWS
7) NEED WATER PRESSURE AND DWV TEST
8) DO NOT DRY IN ROOF UNTIL RE-INSPECTED
9) DO NOT BACKFILL UNTIL OUTSIDE 3" ABS HAS WATER TEST