Permit: T09CM01833

Parcel: 103217250

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
08/28/2009 ROOF NAILING Approved IVRS - Inspection :*
08/19/2009 ROOF NAILING Partial Approval IVRS - Inspection :*
1) OK TO DRY IN
2) MISSING CLIPS AT ENTRY CLOSET JOINT
3) LPC POST CONNECTION 6 X 8 BEAM ENTRY
4) MISSING HARDWARE REAR PORCH PER PLAN SIMPSON EPC44 OR EQUAL POST HEADER W SIMPSON ABE44 OR EQUAL POST TO SLAB
5) T6 TRUSSES 2 POINT BEARING, ALLOW 1/2" FOR DEFLECTION GARAGE WALL
6) MISSING CLIPS HEADERS
08/18/2009 ROOF NAILING Not ready for Inspection IVRS - Inspection :*
08/14/2009 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/13/2009 ROOF NAILING Not ready for Inspection IVRS - Inspection :*