Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T09CM01791

Parcel: 131090410


Addresses:

5730 E 23RD ST

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
09/15/2009 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
08/25/2009 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE SUN SHIELDS OVER CANVAS CONNECTORS
2) PAINT ALL EXPOSED PVC WITH LATEX PAINT
3) SCRATCH ALL THE INK BOX ON UNIT DATA PLATE WITH THE PROPER HEAT STRIP INSTALLED AND FUSE ACCORDINGLY
4) PROVIDE A ROOF JACK FOR SERVICE RECEPTACLE CONDUIT
5) PROVIDE ACCESS TO INSIDE HOUSE AND ATTIC
08/21/2009 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ONE PRESENT FOR ACCESS TO ROOF
2) LADDER NEEDED
3) PLEASE RECALL