Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - ABOVE CEILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/27/2009 | MECHANICAL - ABOVE CEILING | Approved | IVRS - Inspection :* 1) OK FOR TILES-MECHANICAL ONLY |
|
| 08/18/2009 | MECHANICAL - ABOVE CEILING | Partial Approval | IVRS - Inspection :* 1) ITEMS 1-5 DATED 8/14/09 HAVE BEEN CORRECTED PROCEED WITH T-BAR INSTALLATION |
|
| 08/14/2009 | MECHANICAL - ABOVE CEILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE FLEX CONNECTORS TO UNITS PER PLANS 2 PROVIDE CONICAL TAPS WITH 125 PERCENT FREE AIR OF DESIGN PER PLANS 3) FLEX DUCT NOT TO EXCEED 8' PER PLANS INCLUDING EXHAUST 4) PROVIDE FLEX CONNECTIONS AS DESCRIBED IN PLANS 5) PROVIDE R-8 INSULATION ON ALL DUCT IN VENTED ATTIC SPACE |