Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T09CM01621
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/30/2009 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
08/27/2009 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) WATER TEST FROM 3' CONNECTION AT 4" BLDG DRAIN UPSTREAM 3" WYE THRU TO 3 X 2 FOR GREASE TRAP WITH 3" FCO AND 2" FOR FLOOR SINK INSTALLED TO INTERMEDIATE TEST HEIGHT WITH DRAINAGE FITTINGS. 3" BRANCH GOES NORTH EAST 3" WYE WITH END OF KLINE CLEANOUT TO 3" RISER WITH 2" MOP SINK, 3 X 2 WYE FOR FLOOR AINK TO INTERMEDIATE HEIGHT PER REDLINES ON INITALED KP1.0 AND ISOMETRIC ON RWS 8/19/09 KP2.0 |
|
08/26/2009 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) CONTRACTOR CANCELLED |
|
08/23/2009 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) POST YOUR SUITE NUMBER 2) PROVIDE ONE REVISED APPROVED PLAN SHOWING THE WORK TO BE DONE. IF YOU CANNOT FOLLOW THE PLAN, RED LINES MUST BE AVAILABLE AT THE TIME OF INSPECTION-NO EXCEPTIONS |