Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/31/2009 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 07/14/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HAVE LICENSED ELECTRICIAN, IN HIS COMPANY LETTER HEAD THAT ALL ELECTRIC IN THIS ROOM IS SAFE AND TO CODE, INCLUDING WATER HEATER 2) 4 X 6 BEAM AT 12' PLUS SPAN IS UNDERSIZED. HAVE PLANS EXAMINER DETERMINE SIZE AND APPLICATION 3) WATER HEATER PTR LINE SHALL EXTEND OUT TO EXTERIOR AND DISCHARGE DOWNWARD 6" MIN 24" MAX FROM FLOOR OR GROUND |
|
| 07/08/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO APPROVED PLANS ON SITE 2) RECALL |