Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T09CM01586
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/23/2014 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
05/27/2014 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | ALL OK EXCEPT - A REVISION IS NEEDED FOR THE GARAGE SHEAR PANELS AND WHAT SHEAR IF ANY IS NEEDED ON THE NORTH WALL OF THE KITCHEN/DINING AREA | |
05/19/2014 | EXT METAL CLIPS/EXT SHEATHING | Denied | MAKE PREVIOUSLY MENTIONED INSPECTOR NOTES. OK TO WIRE MESH. | |
05/16/2014 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) MANY PLACES OF UN-NAILED OSB ON 1ST AND 2ND FLOOR, ALL SIDES. 2) HOLD DOWNS & BRACED PANELS MUST BE ADDRESSED. 3) EAST PORCH ROOF LEDGER NEEDS POSITIVE ATTACHMENT. 4) REVISE GARAGE OPENINGS TO ADDRESS NEED FOR DRAG-STRUT AND HOLD-DOWNS. 5) TIGHTEN ALL ANCHORS TO SLAB. INSTALL ANCHORS WITHIN 12" OF ANY END OF WALL, DOOR OPENING, OR PLATE SPLICE. INSTALL ANY MISSING ANCHORS. 6) PORCH LEDGER IS MISSING THE H2.5'S FROM TOP OF LEDGER TO STUDS. INSTALL AS PER PLAN OR INSTALL LAG SCREWS PER DETAIL 10/6 |