Permit: T09CM01561

Parcel: 121071750


Addresses:

1525 N ALAMO PL

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
09/15/2009 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
1) APPROVED PER APPROVED PLAN
07/29/2009 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE A CITY APPROVED PLAN THAT IS THIS ACTUAL INSTALLATION
2) THE TEE FITTING USED ON HOT OUTLET IS NOT A SOLDER TYPE AND CONNECTION TO WATER HEATERS FOR SOLAR ARE TYPICAL MINIMUM 1/2" FROM COLLECTOR PANEL
3) SECURE 1/2" GAS PIPING DROP TO WATER HEATER
4) REMOVE TAPE FROM VENTING PIPING AND PROVIDE APPROVED FASTENERS AT ALL JOINTS
5) PIPING ON ROOF TO BE SUPPORTED OFF OF ROOF ON WEATHER RESISTANT MATERIALS AND MADE SECURE