Permit: T09CM01552

Parcel: 10713217A

Inspection Status: Approved

Inspection History: BUILDING - PROGRESS

Permit Number - T09CM01552

Inspection Description - BUILDING - PROGRESS

Inspection Status - Approved

Date Description Inspector Results Comments
07/28/2009 BUILDING - PROGRESS Approved IVRS - Inspection :*
1) OK TO LATHE
2) ALL FRAMING AND FOOTERS OK TO COVER
3) RECEIVED CHECK #179 FOR $75.00
4) RECALL 01090
07/16/2009 BUILDING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LEFT MESSAGE AT 9:30 AM AT 225-8555
2) EXPOSE FOOTERS
3) EXPOSE ALL WOOD COLUMNS
4) EXPOSE BEAM TO POST CONNECTIONS
5) FRONT PORCH RAFTERS 2 X 6 + 2 X 4 OVER SPANNED, SISTER RAFTERS OR INSTALL 12" ON CENTER
6) REMOVE FREEZE BOARD TO VERIFY RAFTER SEAL
7) SOUTH PORCH SAME AS FRONT