Inspection History: FRAMING

Date Description Inspector Results Comments
02/17/2010 FRAMING Approved IVRS - Inspection :*
02/12/2010 FRAMING Partial Approval IVRS - Inspection :*
1) BANG PLATES THRU-OUT
2) BLOCK FOR SHOWER DROP EAR 90
3) NEED SOLAR READY
4) MUD RING UFER CONNECTION GARAGE
5) MISSING BOX FOR GARAGE DOOR (ELECTRIC EYE)
6) VERT BACKING SHOWER SURROUNDS
7) INSULATE HOT H20 LINES BATHROOM