Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T09CM01460

Parcel: 108192180


Addresses:

4490 N 1ST AV


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T09CM01460

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
07/15/2009 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
1) CORRECTIONS MADE OK
2) OK TO COVER
07/14/2009 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEE NOTES ABOVE, THIS IS NOT A COMPLETE LIST, FAILURE TO COMPLY HAS RESOLUTION REINSPECTION FEE. PLEASE HAVE YOUR PLUMBER ON SITE FOR FUTURE INSPECTION
07/10/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection 1) NOT INSTALLED PER PLAN
2) ALL FIELD CHANGES TO THE PLAN ARE TO BE MADE WITH RED INK AVAILABLE AT THE TIME OF INSPECTION
3) NUMEROUS CODE VIOLATIONS INCLUDE, BUT ARE NOT LIMITED TO:
A) ALL PIPING REQUIRED 2 PERCENT SLOPE
B) VENTS CONNECTED TO A HORIZONTAL DRAIN SHALL BE TAKEN OFF ABOVE THE DRAINAGE CENTER LINE, DOWN STREAM OF THE TRAP
C) ALL TRAPS TO BE VENTED
D) TRAP ARMS MAY NOT EXCEED THEIR ALLOWED DISTANCE
E) HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP
F) VERTICAL BY HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP