Permit: T09CM01442

Parcel: 141313550

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T09CM01442

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/19/2009 FRAMING Approved IVRS - Inspection :*
08/18/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WHAT IS UNDER EAST END OF EAST GARAGE BEAM AT EXT. WALL AND SOUTH END OF BEAM AT 1ST FLOOR BEDROOM
2) DRYER VENT RUN IS 27' WITH 1-90 DEGREE BEND AND 2-45 DEGREE BENDS-THE MAX LENGTH IS 15'
3) BANG PLATE 3" ABS AT TOP PLATE IN PANTRY-BOTH SIDES
4) FHA STRAP TOP PLATES AT MASTER LAV ABS OVER BORE
5) SECURE 4 GANG AT MASTER SHOWER
6) BANG PLATE WIRE IN MASTER BED AT TUB
7) NEED GABLE END X BRACING