Permit: T09CM01434

Parcel: 112081130

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
11/02/2009 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
10/23/2009 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SECURE ALL 4 GANG ELECT BOXES
2. MOVE PEX 12" FROM KITCHEN SINK CAN LIGHT
3. REPAIR FIRE BLOCKING ABOVE 1ST FLOOR SHOWER
4. MOVE ALL BEDROOM SMOKE DETECTORS AT LEAST 3' FROM A/C/ REGISTERS - THE FURTHER THE BETTER