Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T09CM01409
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/14/2009 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* 1) NEED ANSWER DETAIL 11/6-DT 1 CALLS FOR X BRACING IS IT REQUIRED, NO WALL BELOW |
|
08/13/2009 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) FINISH ITEMS FROM PREVIOUS INSPECTION 2) NEW TRUSS CALCS REQUIRED 3) NEW SUPPLIER |
|
08/12/2009 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MODEL NUMBER ON PLAN IS CL, CANNOT FIND CL IN TRUSS DRAWINGS 2) WALKED ROOF BROKEN PIECE OF OSB MARKED IN BLACK. REAR PORCH IS VERY BOUNCY CANNOT FIND DETAIL FOR OPEN SPAN, ROOF PLAN SAYS CLIP DBL 2 X 12 TO TRUSS, DETAILS 10-6-11 CALL FOR CROSS BRACING? 3) ALL OSB AT SHEAR GARAGE GOING UP TO ROOF ON MUST BE PERIMETER NAILED 4) FROM LAST INSPECTION 16D .162 DIAMETER NAILS REQUIRED IN ALL PA STRAPS |
|
07/31/2009 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) #3 SHEARWALL INTERIOR GARAGE TO BE BLOCKED 2) #5 SHEARWALL WEST WALL 2ND SHEAR TO REAR MINIMUM 16'-0" 3) MARK ALL MISSED P.A.'S ON CONCRETE FLOOR 4) NAIL ALL P.A.'S WITH CORRECT NAILS .164D 16 COMMON 5) REAR PORCH 2 X 12 CLIP TO TRUSS LTPS AND AT 12" 6) N/WEST SHEAR #6 WRONG CONNECTION AT TRANSFER 7) NEED TRUSS DRAWINGS 8) STOPPED INSPECTION-PLEASE WALK JOB BEFORE CALLING IN |