Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/12/2009 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
| 07/16/2009 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) MISSED 4'-0" OF NAILING NORTH SIDE OF GARAGE PARAPET INTERIOR WALL 2) TJI HAS A PROFILE WEB WIDTH OF 3 1/2 INCHES. QUESTION THIS PLAN CALL FOR L.P.I'S. YOU INSTALLED B.C.I. NEED IN WRITING FROM ARCHITECT OF RECORD FOR SWITCH |
|
| 07/14/2009 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL ALL MISSED ROOF SHEATHING-SEE BLACK MARKS, PLUS NAIL ALL PERIMETER, RENAIL AT RIDGE, WHERE OSB IS BENT OVER RIDGE 2) NAIL ALL STUDS TO WALL SHEATHING AT P.A.S. HT. ECT... (VERTICAL NAILING) 3) PLAN CALLS FOR TJI AT GARAGE, BCI INSTALLED. FIND OUT TOP, BOT CHORD SIZE |