Permit: T09CM01320

Parcel: 133191930


Addresses:

710 N MANN AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/09/2009 FRAMING Approved IVRS - Inspection :*
09/08/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL PROTECT SPRINKLER AT EXISTING FURROUT SOUTH BATH
2) NOTE 4 FROM PREVIOUS
3) BLOCK BOOTS 3 SIDES
4) OK TO INSULATE
08/27/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DRYER VENT IS WRONG-REPLACE ALL AND MUST BE ALL SOLID DUCT-NO FLEX IN WALL
2) TPR DRAIN MUST RUN OUTSIDE-NOT WHERE IT IS IN CONDENSATE DRAIN
3) FIREBLOCK DROP CEILINGS
4) BLOCK DUCT BOOTS