Permit: T09CM01311

Parcel: 106011140


Addresses:

525 E PASTIME RD

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/17/2009 FRAMING Approved IVRS - Inspection :*
1) NOTE: OLD GAS ?
2) CONDENSATE
3) TAPE DBL/SINGLE
4) TWO CONDENSATES REQUIRED
5) ONE COMB/RELIEF DUCT METHOD OK
6) RANGE USE 20 AMP BREAKER
07/13/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SECURE ALL WIRING TO CODE
2) DISHWASHER ? CIRCUIT #13 PER PLAN
3) ALL LUMBER SOLE PLATES MUST BE TREATED LUMBER
4) FIREBLOCK DROPPED CEILINGS
5) JUNCTION BOX AT ENTRY NOT ACCESSIBLE
6) PROVIDE APPROVED CEILING FROM NOTES
7) SMOKE ALARM WIRING IN APPROVED BOXES INTERCONNECTED MINIMUM 36" FROM FORCED AIR REGISTERS
8) COMBUSTION AIR WATER HEATER ROOM EXTEND RELIEF LINE TO EXTERIOR 1" CLEARANCE
9) MAKE UP ALL EXHAUST FANS B-VENT