Inspection History Details
Inspection Status: Partial Approval
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T09CM01281
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Partial Approval
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/28/2010 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) KITCHEN AREA SOIL PIPING OK, RECALL FOR FD AND FS CONNECTIONS, WRAPS IN PLACE 2) PERM CAP ANY ABANDONED DRAINS THAT ARE STILL CONNECTED TO SANITARY BLDG DRAIN |
|
| 04/27/2010 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BACK PITCH AT WATER CLOSET DRAIN 2) GW HAS BACK PITCH AND FLAT SECTION 3) VENT TAKE OFF AT FD NOT INSTALLED AT MIN 45 DEGREE, TRY A WYE WITH A 1/16" BEND AND SWEEP 4) WILL NEED TO RETEST UNDERGROUND AT TIME OF INTERMEDIATE INSPECTION OR INSTALL ABOVE FLOOR TEST TEES NOW |
|
| 04/22/2010 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE AN APPROVED DRAINAGE FITTING FOR TEST TEE 2) PROVIDE 1/4" PER FOOT SLOPE 3) ALL FIXTURES VENTS SHALL RISE VERTICALLY ABOVE FLOW LINE 4) FD CONNECTS TO GW 5) FS AT 3 COMP CONNECTS TO SANITARY 4" UPPER TERMINAL CLEANOUT REQUIRES |
|
| 04/06/2010 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* HAMMER ARRESTORS REQUIRED REMOVE EXCESS FLEX FROM SOLDIER JOINTS, OK TO INSULATE PER PLAN SPECS. INSULATE ALL COPPER TOUCHING MSTAL 2" CW SPECIFIED ON PLAN TO FIRST BRANCH. ALSO RPOVIDE 1 1/2 C THRU FLUSHOMETER BRANCH BEFORE REDUCING. RELINE CHANGE OF LOCATION OF P-3 FIXTURES SECURE LAV CARRIERS. |
|
| 03/10/2010 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) BELOW SLAB PIPING OK FOR CONCRETE 2) WILL INSPECT PIPING IN CRAWL SPACE WHEN IT IS READY, I.E. SUPPORTS 3) DWV TEST OK PENDING CRAW SPACE INSPECTION |
|
| 02/12/2010 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PLEASE POST ADDRESS 2) A DRAIN MAY NOT CONNECT TO A VENT |
|
| 02/11/2010 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* PLANS & PERMITS REQUIRED TO BE POSTED AT ALL TIMES. USE CAR?? TO KEEP SEWER PIPING CAPPED OR PLUGGED |