Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - PROGRESS
Permit Number - T09CM01223
Inspection Description - PLUMBING - PROGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/15/2009 | PLUMBING - PROGRESS | Approved | IVRS - Inspection :* 1) CLOSET FLANGES OK |
|
09/24/2009 | PLUMBING - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TEST TO BE THRU ROOF ON DWV PIPING. OVERHEAD DWV TO BE SUPPORTED AT 4' INTERVALS. PROVIDE ISOLATORS FOR PEX THRU STUD HOLES 2) NOTE: IF SOLDERING OF HOSE BIB IS REQUIRED AT FINISH PROVIDE ADDITIONAL COPPER IN WALL TO PREVENT TRANSITION DAMAGE 3) PROVIDE MID SPAN SUPPORT FOR VERTICAL DWV 4) PROVIDE 18" MINIMUM IN WALL COPPER AT WATER HEATER STUN OUTS 5) GAS TEST GAUGE IS NOT FUNCTIONAL 6) PLEASE CALL IN ALL INSPECTIONS AS REQUIRED FOR APPROVAL 7) INSTALL DRAINAGE FITTINGS AT KITCHEN SINK OR RETEST AT LATER DATE |
|
09/22/2009 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1) SHOWER LINER TEST OK |
|
09/09/2009 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) SHOWER PAN TO BE TESTED TO ROUGH THRESHOLD. 2) LINER MAY NOT BE SCREWED OR PERFORATED LESS THAN ONE INCH ABOVE THRESHOLD 3) WEEPHOLES MAY NOT BE SEALED SHUT. 4)PAN IS TO DRAIN COMPLETELY WHEN THE PLUG IS REMOVED |
|
09/02/2009 | PLUMBING - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ALL HOSE BIBS REQUIRE VACUUM BREAKERS, EVEN DURING CONST. 2) INSTALL VACUUM BREAKER OR REMOVE HOSE CONNECTIONS 3) 2ND LEVEL SHOWER PAN DENIED, SEE INFORMATION HAND OUT OF CODE REQUIREMENTS WITH PICTURES 4) SLOPE BACKING AND LINER HEIGHT |
|
08/14/2009 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
07/09/2009 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1) IN WALL WATER DISTRIBUTION FOR 2ND LEVEL BATH 203 ONLY. WATER TEST-OK |