Permit: T09CM01206

Parcel: 140260370

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T09CM01206

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
10/27/2009 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
09/02/2009 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) PROVIDE TEST ON ALL UNDERGROUND PIPING AFTER REPAIR PIPING AND FITTING FOR WATER CLOSET
08/20/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection VENT FOR BLDG SEWER. ABS IS NOT PERMITTED TO BE USED WITH RECTOR SEAL #5 REMOVE AND REPLACE FITTING - USE APPROVED THREAD JOINT COMPOUND.
OK TO COVER UNDERGROUNG PORTION OF VENT
08/14/2009 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) WATER TEST THRU BLDG AND BACK WATER VALVE AND DOWN STREAM CLEANOUT TO 6' BLDG EXTERIOR OK
2) WILL NEED RETEST FOR BACK WATER MAIN SEWER VENT
08/13/2009 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEE NOTE #2 ABOVE POST THIS ADDRESS
2) HAVE PIPING UNDER TEST WHEN CALLING FOR INSPECTION