Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T09CM01177

Parcel: 125042870


Addresses:

1933 E HAWTHORNE ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
11/16/2009 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
11/02/2009 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LOOSE WIRES AT HALL TO EXISTING HOUSE
2) ELECTRIC BOX IN GARAGE (GFI MAYBE) NOT TERMINATED TO OUTSIDE
3) ELECTRIC SERVICE PANEL SHALL REST ON PLYWOOD BACKING, NOT OVER FOAM