Permit: T09CM01175

Parcel: 103217410

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/30/2009 FRAMING Approved IVRS - Inspection :*
06/26/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE BATH BLOCKING PER HOME INCLUSIVE
2) NOTES 1 & 3 FROM PREVIOUS
3) PROVIDE ATTIC ACCESS PER PREVIOUS NOTE 7
06/25/2009 FRAMING Not ready for Inspection IVRS - Inspection :*
06/23/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED APPROPRIATE BLOCKING FOR BATHROOM GRAB BARS
2) RE-ATTACH BOX FOR KITCHEN EXHAUST
3) NAIL STOP 2" VENT HALL BATH
4) NEED 12" CLEARANCE PEX TO CAN LIGHT IN HALL
5) NO SUPPLY OR DWV TEST
6) NAIL STOP 1 1/2" VENTS MASTER
7) DUCT RUNING THRU ATTIC ACCESS OPENING