Permit: T09CM01136

Parcel: 12620001C

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T09CM01136

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/10/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
06/09/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE LISTING, PROOF OF 1" AIR GAP OR CORRECT BACKFLOW PROTECTION FOR WATER TO PRO-CLEAN AT
3-COMP SINK - FOR CHEMICAL ADDITION
06/08/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. CALL IN ALL INSPECTIONS
2. PROVIDE LONG RADIUS FITTING FOR INTERCEPTOR VENT BELOW FLOOD RIM
3. VENT FROM INTERCEPTOR TO BE 1' FROM SIDE WALL OBSTRUCTION
4. PROVIDE LISTING FOR BACKFLOW PROTECTION FOR CHEMICAL ADDITION AT 3-COMP SINK OR (PROVIDE IT) OR PROOF OF 1" AIR GAP
5. CAULK FIXTURES AT WALL