Date Description Inspector Results Comments
06/03/2009 EXT METAL CLIPS/EXT SHEATHING Approved
05/28/2009 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) WALKED ROOF, NAILING OK
2) GARAGE DETAIL 13/DT1=SIMP. STRAP ST2115 ON INSIDE 2 X 4 BLOCKS MST. 48 6-0" LONG OUTSIDE (MST STRAP 1 1/2" WIDE)
3) CROSS SECTION DETAILS, REFER TO SD PAGES, PLANS HAVE DT ONLY
4) GABLE ENDS HINGE BRACING AND SHEAR TRANSFER CONNECTION AT 4'-0" PANELS NOT DONE (REAR WALL)
5) CARPENTERS NEED SAME PLAN, APPROVED FOT THIS JOB
6) X BRACE TRUSSES AT EACH END