Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T09CM01107
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/24/2009 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
07/20/2009 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) TRUSS DRAWINGS CALL FOR T.J.I. 560'S, B.C.I. 5,000 INSTALLED 2) SUPPORT A-14 TRUSS AT BEARING PT. 3) NAIL ALL STUDS ATTACHED TO P.A.'S OR HTT'S 4) RENAIL AT RIDGE BENT OVER OSB 5) NAIL AT ALL BLACK MARKS ON ROOF |