Permit: T09CM01086

Parcel: 129022630


Addresses:

2801 E EXETER ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
06/16/2009 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
06/15/2009 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) COMPLETE SMOKE ALARMS IN APPROVED BOXES
2) RELOCATE MASTER JUNCTION
06/12/2009 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. ALL WORK TO CODE
2. SUBMIT ELEC. PLAN, PLUMBING PLAN - ALL WORK DONE
3. INSTALL HARD-WIRED SMOKE ALARMS BEDROOMS AND HALLWAYS
4. ACCESS PANELS FOR JUNCTION BOXES - MASTER CLOSET
5. BOND GAS LINE
06/08/2009 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. BOX OVERFILLED
2. PLEASE PROVIDE GROUND TAILS FOR SWITCHES
3. PROTECT CONDUCTOR FROM SCREWS INSIDE OF BOXES
4. SECURE BOX IN WALL
5. PROTECT M/C CABLE IN SHALLOW CHANNEL
6. USE APPROVED BOX WITH M/C CABLE
7. SUPPORT M/C WITHIN 12" OF BOX
8. SUPPORT NM CABLE WITHIN 12" OF CANS & EXHAUST FANS AND BOXES
9. CABLES TO BE CLAMPED OR SECURED TO BOXES (ALL)
10. EXPOSED NM CABLE BACK PORCH
11. PROVIDE OUTLETS PER 210.52
12. PROVIDE LIGHT OUTLETS PER 210.70
13. MAKE UP ALL BOXES
14. WHERE ARE SMOKE DETECTORS
15. PROTECT CABLES FROM SHARP METAL EDGES OF CONDUITS
16. JUNCTION BOXES TO BE ACCESSIBLE
17. UNCOVER UNDERGROUND TO INSPECT
18. GROUND METAL JUNCTION BOXES