Date Description Inspector Results Comments
05/28/2009 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/27/2009 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) DON'T LOAD ROOF
2) 2 X 2 X 4 CONTINOUS DOWN TO FLOOR
3) SHIM 3 PT BEARING TRUSS BOTTOM CHORD TO DBL T-PLATE PUT STUDS BELOW
05/22/2009 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1. SHEAR WALL CONNECTION DBL. TOP PLATE TO TRUSS BOTTOM CORD H3.5 24" O.C. DETAIL X ON SD1 (ALL WALLS AT PARALLEL)
2. ROOF HIP SUPPORT, FLAT TRUSS AT PEAK FRONT 2ND FLR
3. A08 TRUSS ROOF 3PT BEARING VERT BLK BETWEEN FLRS
05/21/2009 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) TOO WET
2) PLEASE RECALL