Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/07/2009 | PLUMBING - INTERMEDIATE | Approved | ||
| 07/17/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) HAMMER ARRESTORS INSTALLED ABOVE CEILING-OK 2) INSULATION-OK 3) RWLS IN OVERHANG-OK 4) PARTIAL BECAUSE OF PLAN REVISION REQUIRED FOR WATER PIPE SIZE |
|
| 07/16/2009 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSULATION NOT PER SPEC 15B2-2 ON P-3 2) NEEDS TO BE CONTINOUS ALONG PIPE WITH SADDLES AT PIPE HANGERS 3) OK TO COVER WALLS 4) PROVIDE SWEEPS ON RWL'S |
|
| 07/15/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) DVW WITH TEST THRU ROOF-OK 2) DOMESTIC WATER IN WALLS OK, OVER HEAD NOT ROUTED PER PLAN AND SIZE DISCREPENCEY AT 1 1/2 SERVICE 3) WATER HAMMER ARRESTORS SPECIFIED 4) OK TO INSULATE PER PLAN 5) RECALL FOR INSPECTION 6) CLOSET FLANGES SET ON CONCRETE FLOOR, REQUIRE REINSPECTION IF INSTALLING TILE 7) PLUG STINKING SEWER PIPE |
|
| 07/14/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) REMOVE WALL INSULATION AT PIPING UNTIL TESTING IS COMPLETE 2) OK TO INSULATE HW PER PLAN SPEC |