Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
Permit Number - T09CM01041
Inspection Description - MECHANICAL - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/09/2010 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* | |
10/27/2010 | MECHANICAL - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
10/20/2010 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
10/07/2010 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
10/06/2010 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
09/23/2010 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
09/17/2010 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) 2ND LAYER FIRE WRAP OK |
|
09/16/2010 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. GREASE DUCT WELD TEST OK 2. 1ST LAYER OF FIRE WRAP OK 3. 2ND LAYER THROUGH ROOF PENETRATION OK THIS IS AN AFTER HOURS INSPECTION CK#6142 IN THE AMOUNT OF $165.00 PAID TO C.O.T HAS BEEN RECEIVED. |
|
09/15/2010 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
08/31/2010 | MECHANICAL - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
06/25/2010 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
06/24/2010 | MECHANICAL - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
06/11/2010 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1 - ALL ITEMS DATED 5-19-2010 HAVE BEEN COMPLETED 2 - PER CODE, CONVEYOR PIZZA OVENS REQUIRE A TYPE 1 HOOD & FIRE SUPPRESSION SYSTEM, SEE SECTION 506 OF IMC |
|
06/02/2010 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) ITEM 1 DATED 5/19/10 STILL NOT CORRECTED, ALL OTHER ITEMS HAVE BEEN CORRECTED |
|
05/25/2010 | MECHANICAL - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
05/19/2010 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) S/A DUCT ABOVE RESTROOMS TO BE INSULATED 2) NO FLEX DUCT PER PLANS 3 SPECS 3) SEAL ALL DUCT AT BATTERY EXHAUST 4) INSULATE DUCT ABOVE RECEIVING LOUNGE 5) SEAL ALL DUCT 6) PROVIDE 45 PERCENT CONVERING TAPS PER PLANS 7) THIS NOT A COMPLETE INSPECTION 8) THIS IS A COURTESY INSPECTION |