Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - PROGRESS
Permit Number - T09CM01041
Inspection Description - PLUMBING - PROGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/17/2010 | PLUMBING - PROGRESS | Approved | ||
09/14/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1) UNDERGROUND AT DEMO ROOM 2) OK TO COVER |
|
09/09/2010 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
09/09/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1) OK TO COVER WALLS AT ROTISSIERIE AND DELI PREP TO ABOVE CEILING S.T.O.I. (AFTER PIPE INSULATION) |
|
08/31/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1) OK TO COVER UNDERGROUND AT ROTISSERIE AND DELI PREP |
|
08/30/2010 | PLUMBING - PROGRESS | Cancelled | IVRS - RI canceled | |
08/27/2010 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
08/26/2010 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) REQUIRE REVISED APPROVED PLAN |
|
08/24/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1) AT BAKERY-OK TO COVER UNDER FLOOR 2) WATER AND DWV TO ABOVE CEILING OK TO COVER |
|
08/20/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1) 3-COMP SINK IN BAKERY IS MOVING 15' TO NORTH IN BAKERY, ADDITION OF 4" FLOOR SINK AND 2" DIRECT DRAIN FOR 3-COMP SINK WATER TEST PER RED LINE UNDERGROUND TO CLEANOUT HEIGHT ONLY 2) NEED TO SEE DEMO AT OLD LOCATION 3) DEMO CAPS IN MEAT PREP FLOOR OK |
|
08/19/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1) DWV WATER TEST VENTS FD-7 36" + FD-7 72" TO POINT OF EXISTING 2) DWV WATER TEST 3-COMP DRAINAGE, FLOOR SINK PER RED LINE, HAND SINK + 4" END OF LINE WALL CLEANOUT PER REDLINE OK PENDING REVISED CITY APPROVED PLAN 3) WATER DISTRIBUTION FOR 3-COMP SINK AND HAND SINK & HOSE STATION WITH INSULATION OK 4) PROVIDE PERM CAPS ON ALL FLOOR DEMO PIPING IN MEAT PREP BOX |
|
08/18/2010 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) TRAILER LOCKED 2) NO MESSAGE |
|
08/17/2010 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) BOTH TRAILER DOORS ARE LOCKED 2) PRODUCE PREP NOT COMPLETE 3) OCCUPATION OF ANY AREA IS SUBJECT TO BLDG INSPECTOR , WILL REQUIRE APPROVED PLAN |
|
08/16/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* AT PRODUCE PREP OK TO COVER WALL SUBJECT TO REVISED APPROVAL PLAN. SERVICE SINK AT JANITOR CLOSET OK TO COVER REQUIRE ADDITIONAL HANGERS OVERHEAD |
|
08/11/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* MEAT PREP: 1) 4" FLOOR SINK, 2" DRAIN FOR 2 COMP SINK, 2" DRAIN FOR HAND SINK AND 3" TROUGH DRAIN PRODUCE PREP: 1) 4" FLOOR SINK AND 4" END OF LINE CLEANOUT WITH HAND SINK |
|
08/10/2010 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) 2 COMPARTMENTS OF 3 COMP SINK TO BE DIRECTLY CONNECTED TO SANITARY SEWER IF ONE COMPARTMENT IS SANITIZER IT IS TO BE INDIRECTLY CONNECTED 2) PLANS DO NOT SHOW FLOOR SINK FOR I.W. CONNECTION 3) PLANS SHOW 3" WASTE FOE FLOOR SINK THIS IS NOT ON THE APPROVED PLAN |
|
08/06/2010 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
08/04/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1) CLOSET FLANGE AT TIRE SHOP OK |
|
08/02/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* TIRE AND BATTERY RESTROOM: 1) INSULATION TO ABOVE CEILING OK 2) DWV TO ABOVE CEILING OK 3) NEED TO SEE CLOSET FLANAGE |
|
08/02/2010 | PLUMBING - PROGRESS | Not ready for Inspection | 1) FURNACE REPAIR COUPLINGS NOT PERMITTED IN OR UNDER A BLDG 2) OK TO INSULATE WATER PIPING |
|
07/29/2010 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) PVC DWV VERTICAL SUPPORT 2) SUPPORT ALL COPPER STUB OUTS 3) CAP OFF DEMO'ED COPPER IN THE WALL |
|
07/28/2010 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) TRAILER LOCKED AND NO CONTACT NUMBER |
|
07/12/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1) DEMO FLOOR SINK IN RECEIVING OK 2) TRENCH DRAINS OK |
|
07/01/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1) SNACK BAR FINAL OK S.T.O.I. |
|
06/25/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1) THIS INSPECTION FOR BACKFLOWS INSTALLED IN EXISTING SERVING AREA, WAITING ON CERTIFICATIONS FOR BACKFLOW DEVICE, TO BLDG INSPECTOR |
|
06/21/2010 | PLUMBING - PROGRESS | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* |
|
06/21/2010 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) 3 COMP SINK DRAINAGE INSTALLED WITH EXISTING PIPING LAYOUT OK |
|
06/11/2010 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) RE-READ NOTE NUMBER 1 FROM 6/9/10 (CORRECTED) 2) RE-READ NOTE NUMBER 5 FROM 6/9/10 3) BAFFLE TEE MAY NOT BE INSTALLED IN HORIZONTAL POSITION OK 4) INSPECTOR IS OK FOR OCCUPATION WHILE CORRECTIONS ARE BEING MADE |
|
06/02/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1) JANITORS CLOSET AND FAMILY RESTROOM OK THRU ROOF |
|
05/24/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1) 3" PVC FLOOR DRAIN INSTALLED 2) ABS DWV FOR FAMILY RESTROOM OK TO COVER 3) 4" CWV AT BAKERY OK TO COVER 4) #T10CM00197 |
|
05/21/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* | |
05/18/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* MOP SINK NEXT TO RESTROOMS OK TO COVER |