Permit: T09CM01041

Parcel: 105095510


Addresses:

4701 N STONE AV


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T09CM01041

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
11/17/2010 PLUMBING - INTERMEDIATE Approved
06/29/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) FAMILY BATHROOM FINAL OK
2) AT SNACK BAR SECURE FIXTURES AND CAULK FIXTURES
3) AIR GAP STRICKLY ENFORCED
4) CWV VENTS TO BE REPAIRED ASAP
06/25/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) FAMILY TR FLANGE OK
2) AT SNACK BAR; SECURE AND SEAL ALL FIXTURES
3) COMPLETE BEV INSTALLED, LABEL ALL BACKFLOW ASSEMBLIES
4) PROVIDE CERTS
5) COMPLETE WATER HEATER INSTALL
6) UPC SECTIONS 602.2 AND 603.0 REQUIRE BACKFLOW PROTECTION ON EACH PIECE OF EQUIPMENT THAT MAY CAUSE POLLUTION OR CONTAMINATION OF THE POTABLE WATER SUPPLY
06/24/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
06/09/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) 3 LAVS MAY BE SET SIDE BY SIDE AND SERVED BY A SINGLE OUTLET, WHEN THEY ARE SET WITHIN THE ALLOWED DISTANCE (30" CENTER LINE TO CENTER LINE)
2) WATER FLEXES MAY NOT BE STRUNG TOGETHER TO MAKE UP THE WATER SUPPLY
3) SUPPORT MIXING VALVES
4) AT TRUCKERS RESTROOM CUT DOWN CLOSET BEND TO BE FLUSH WITH THE TOP OF THE CLOSET RING
5) WATER CLOSETS ARE TO BE SET AT LEAST 15" FROM CENTER TO SIDE WALL OR OBSTUCTION. HANDICAPPED WATER CLOSETS REQUIRE 18" FROM SIDE WALL OR OBSTRUCTION TO CENTER
6) STERILIZE WATER SYSTEM ACCORDING TO SPECS
7) I DIDN'T SEE THE HOSE BIBBS UNDER THE LAVS
06/03/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) CLOSET FLANGES IN BOTH FAMILY RESTROOMS OK
05/10/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*