Permit: T09CM01027

Parcel: 14108528A


Addresses:

6692 S MEMORIAL PL

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/11/2009 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
08/04/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) CLOSET FLANGES ALL-OK
07/31/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) 2ND LEVEL CLOSET FLANGES-OK
07/27/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) 1ST LEVER CLOSET FLANGES-OK (GANG RESTROOMS ONLY)
07/22/2009 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
07/17/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) WATER DISTRIBUTION FROM 2" AT EXTERIOR THRU BLDG TO ALL FIXTURES AND STOPPED AT 1 1/4" VALVE 2ND LEVEL TO CONTINUE TO COOLERS AT LATER DATE. OK TO COVER AFTER INSULATION 2ND LEVEL
07/15/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) DWV WATER TEST THRU ROOF-OK
2) WATER DISTRIBUTION 1ST LEVEL IN WALL AND OVERHEAD INCLUDING ROOM 113 WITH STUB UP TO 2ND LEVEL AIR TEST-OK
07/13/2009 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) PROVIDE REQUIRED VENT FOR FIXTURE UNITS IN 1ST AND 2ND LEVEL RESTROOMS
2) NOTE: REQUIRED BLDG DRAIN IS 4" WHICH SHALL MEET MINIMUM REQUIRED CROSS SECTIONAL AREA OF VENT THRU ROOF