Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROOF DRAINS
Permit Number - T09CM00963
Inspection Description - PLUMBING - ROOF DRAINS
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/24/2010 | PLUMBING - ROOF DRAINS | Approved | IVRS - Inspection :* | |
| 06/23/2010 | PLUMBING - ROOF DRAINS | Not ready for Inspection | IVRS - Inspection :* | |
| 06/22/2010 | PLUMBING - ROOF DRAINS | Partial Approval | IVRS - Inspection :* 1) CORRECTIONS OK 2) NEED LETTER FOR DELETION OF INSULATION |
|
| 06/17/2010 | PLUMBING - ROOF DRAINS | Partial Approval | IVRS - Inspection :* TEST ON RUNS OK HORIZONTAL 45DEG OFFSETS AT 30' INSTALLED PER JAMIE TIGLAS PE. SUPPORTS NEEDED OK TO INSULATE PER PLANS SPECS |
|
| 06/15/2010 | PLUMBING - ROOF DRAINS | Not ready for Inspection | IVRS - Inspection :* | |
| 06/11/2010 | PLUMBING - ROOF DRAINS | Not ready for Inspection | IVRS - Inspection :* | |
| 06/02/2010 | PLUMBING - ROOF DRAINS | Not ready for Inspection | IVRS - Inspection :* | |
| 04/26/2010 | PLUMBING - ROOF DRAINS | Not ready for Inspection | IVRS - Inspection :* | |
| 04/22/2010 | PLUMBING - ROOF DRAINS | Not ready for Inspection | IVRS - Inspection :* | |
| 04/15/2010 | PLUMBING - ROOF DRAINS | Not ready for Inspection | IVRS - Inspection :* | |
| 04/12/2010 | PLUMBING - ROOF DRAINS | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STRAIGHT RUN OF PVC RWL'S WILL REQUIRE A METHOD TO CONTROL EXPANSION AND CONTRACTION WITH PLAN REVIEW, NOTE YOUR OTHER STORES UTILIZED CAST IRON TO MIDIGATE THIS PROBLEM |