Permit: T09CM00931

Parcel: 10709066D

Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
04/30/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) UNABLE TO LOCATE GAS/OR ELECTRIC METERS
2) NEED ACCESS TO INTERIOR
3) POWER CORD CONNECTION FROM SERVICE TO M/H GRD. WIRE CUT OFF, J-BOX AND CONNECTIONS NOT DONE IN A WORKMANSHIP MANNER, COVER MISSIN FROM BOX SPLICES IN DIS-REPAIR
4) 50 AMP POWER CORD, ON A 60/60 BREAKER, MISSING PANEL IN SERVICE PEDESTAL, EXPOSED ENGERGIZED PARTS
5) LABEL SERVICE PLATE FOR SPACE NUMBER METAL LABEL
6) MISSING POWER CORD RESTRAINT AT J-BOX
7) ODOR OF SEWER GAS AT H20 HTR AREA
8) H20 HTR TO BE PROTECTED FROM ELEMENTS
9) USED H20 HTR
10) GRD SPLICE NEED WIRE NUT