Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/30/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) UNABLE TO LOCATE GAS/OR ELECTRIC METERS 2) NEED ACCESS TO INTERIOR 3) POWER CORD CONNECTION FROM SERVICE TO M/H GRD. WIRE CUT OFF, J-BOX AND CONNECTIONS NOT DONE IN A WORKMANSHIP MANNER, COVER MISSIN FROM BOX SPLICES IN DIS-REPAIR 4) 50 AMP POWER CORD, ON A 60/60 BREAKER, MISSING PANEL IN SERVICE PEDESTAL, EXPOSED ENGERGIZED PARTS 5) LABEL SERVICE PLATE FOR SPACE NUMBER METAL LABEL 6) MISSING POWER CORD RESTRAINT AT J-BOX 7) ODOR OF SEWER GAS AT H20 HTR AREA 8) H20 HTR TO BE PROTECTED FROM ELEMENTS 9) USED H20 HTR 10) GRD SPLICE NEED WIRE NUT |