Permit: T09CM00855

Parcel: 123120080


Addresses:

1507 E SENECA ST


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T09CM00855

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
02/02/2010 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
01/28/2010 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1) NEED PRESSURE TEST GAS
2) NEED POT H20 TEST
3) MOVE PEX LINES 12" FROM LIGHT CANS, 6" FROM FLUES
4) H20 HTR ROOM 1' SQ IN FOR EACH 3,000 BTU AND FURNACE
5) BANG PLATES, NAIL PROTECT ALL PIPES AND WIRES
6) TO TERMINATE COMB/RELIEF INTO ATTIC, IT MUST HAVE CROSS VENTILATION=GABLE END VENTS
7) FINISH INTERIOR PLUMBING
8) INSTALL CONDENSATE